Yokogawa TX10 - Digital Thermometers Series SingleFunction)TX10 Series offers thermocouple thermometers that support K, J, E and T type thermocouples. There are three models available: 1-channel single-function, 1-channel multi-function, and 2-channel multi-function models.
Specifications:
Specifications - Model TX10-01
Number of Input channel | 1 |
---|---|
Measuring Range | Type E: -200 to 700°C (-328 to 1292°F) Type J: -200 to 1000°C (-328 to 1832°F) Type K: -200 to 1372°C (-328 to 2501.6°F) Type T: -200 to 400°C (-328 to 752°F) |
Resolution | -200.0°C to 199.9°C: 0.1°C 200°C or above: 1°C |
Accuracy | +200 °C or above, or when 1°C resolution is set ±(0.2% of rdg + 1°C) -100.0°C to 199.9°C ±(0.1% of rdg + 0.7°C) -200.0°C to -100.1°C ±(0.1% of rdg + 1.0°C) |
Temperature Coefficient | ± (0.015% of rdg +0.06°C)/°C |
Approx. Measurement Interval | 1 sec |
Display Item | HOLD, °C, ch A, TC type K, J, E, T, Battery alarm |
Other Functions | Auto power-off, battery alarm |
Display | LCD |
Operating Temperature | 0 to 50 ºC |
Humidity | 80% RH (no condensation) |
Power Requirements | Two AA-size alkaline dry batteries (LR6) |
Battery Life | About 450 hours |
Drip-proof Construction | Conforms to IP54 (dust-proof and drip-proof requirements of IEC529) |
Compliance with Standards | EMC Standards EMI (interference signal): EN55011;1998, EN61326-1;1998+A1 (Class B, Group 1) EMS (immunity): EN50082-1;1997, EN61326;1998+A1 |
Approx. Height | 151 mm |
Approx. Width | 56 mm |
Approx. Depth | 33 mm |
Approx. External Weight | 180 g |
Supplied Accessories | Two AA-size alkaline dry batteries (LR6) and instruction manual |
Optional Accessories | Extension Cable 5 m (2459 21)/10 m (2459 22) Soft case (930 12) Temperature Probes (for K type thermocouple) Rounded end probe (900 20B, 900 21B, 900 22B) Needle probe (900 23B, 900 24B) Surface probe (900 30B, 900 31B, 900 32B, 900 33B) Bead TC (2459 07) Waterproof Cover (5-per package) (930 11) |
Applications
- Temperature management in a refrigerated warehouse
- Frozen food products quality control
- Perishable foods quality control
- Temperature management in production processes
- Product temperature measurement test
- Temperature checks in equipment maintenance
- Temperature management for research and development
Features
- TC Type
Select the thermocouple type (K, J, E, and T) for the initial setting. (The type K is factory-set at shipment) - Operation
Press and hold down the TC TYPE key while pressing the POWER key. The TX10 enters the thermocouple type selection mode, and each press of the TC TYPE key switches between the thermocouple types. Then accept the setting with the POWER key. (Make sure that the characters in the display have changed.) - Data Hold
Press this key to hold the measured value.
Specifications - Model TX10-02
Number of Input channel | 1 |
---|---|
Measuring Range | Type E: -200 to 700°C (-328 to 1292°F) Type J: -200 to 1000°C (-328 to 1832°F) Type K: -200 to 1372°C (-328 to 2501.6°F) Type T: -200 to 400°C (-328 to 752°F) |
Resolution | -200.0°C to 199.9°C: 0.1°C or 1°C (when 1°C resolution is set) +200°C or above: 1°C |
Accuracy | +200 °C or above, or when 1°C resolution is set ±(0.2% of rdg + 1°C) -100.0°C to 199.9°C ±(0.1% of rdg + 0.7°C) -200.0°C to -100.1°C ±(0.1% of rdg + 1.0°C) |
Temperature Coefficient | ± (0.015% of rdg +0.06°C)/°C |
Approx. Measurement Interval | 1 sec |
Data Storage | Capable of storing up to 10 measured data items |
Simplified Correction | Correction range: ±20°C of measured value |
Display Item | HOLD, RCD, REL, ADJ, MAX, MIN, MEM, °C chA, TC type K, J, E, T Battery alarm |
Other Functions | Auto power-off, battery alarm |
Display | LCD |
Operating Temperature | 0 to 50 ºC |
Humidity | 80% RH (no condensation) |
Power Requirements | Two AA-size alkaline dry batteries (LR6) |
Battery Life | About 450 hours |
Drip-proof Construction | Conforms to IP54 (dust-proof and drip-proof requirements of IEC529) |
Compliance with Standards | EMC Standards EMI (interference signal): EN55011;1998, EN61326-1;1998+A1 (Class B, Group 1) EMS (immunity): EN50082-1;1997, EN61326;1998+A1 |
Approx. Height | 151 mm |
Approx. Width | 56 mm |
Approx. Depth | 33 mm |
Approx. External Weight | 180 g |
Supplied Accessories | Two AA-size alkaline dry batteries (LR6) and instruction manual |
Optional Accessories | Extension Cable 5 m (2459 21)/10 m (2459 22) Soft case (930 12) Temperature Probes (for K type thermocouple) Rounded end probe (900 20B, 900 21B, 900 22B) Needle probe (900 23B, 900 24B) Surface probe (900 30B, 900 31B, 900 32B, 900 33B) Bead TC (2459 07) Waterproof Cover (5-per package) (930 11) |
Applications
- Temperature management in a refrigerated warehouse
- Temperature checks in equipment maintenance
- Temperature management for research and development
Features
- Memory-in Function
Up to ten data items can be stored. When recalled, the stored data value is displayed with its memory number. - User calibration function
Calibration and adjustment can be mode easily by operating the panel keys on instrument and a measurement-standard. - Thermocouple type (K, J, E, and T) select key
- Input channel select key
With each press, the channel switches through the sequence of "chA," "chB," and then "chA-chB." - Data hold key
A held measured value, can be stored in the memory of an optional memory number, which is selected with the up, down keys. - Maximum and minimum record key
Stores the maximum and minimum values from the time the RECORD key is pressed. - Data record key
Stores the held measured value in memory. (Up to ten) - Resolution select key
With each press, resolution alternates between 0.1ºC and 1ºC. (Within the range of -200.0ºC to 199.9ºC) - Maximum and minimum values, and stored data read key
Every time this key is pressed, the maximum and minimum values, stored data, and the current measured data are displayed in sequence. - Relative display select key
Displays measured values with reference to the value obtained immediately before this key was pressed (relative value). Each press of this key can select or release the relative display. - Simplified correction mode key
Sets the correction value, and selects active/inactive of the simplified correction function. - Data call-up key
Used to select a memory number when calling up stored data. Also used to adjust the correction value for simplified correction mode.
Specifications - Model TX10-03
Number of Input channel | 2 |
---|---|
Measuring Range | Type E: -200 to 700°C (-328 to 1292°F) Type J: -200 to 1000°C (-328 to 1832°F) Type K: -200 to 1372°C (-328 to 2501.6°F) Type T: -200 to 400°C (-328 to 752°F) |
Resolution | -200.0°C to 199.9°C: 0.1°C or 1°C (when 1°C resolution is set) +200°C or above: 1°C |
Accuracy | +200 °C or above, or when 1°C resolution is set ±(0.2% of rdg + 1°C) -100.0°C to 199.9°C ±(0.1% of rdg + 0.7°C) -200.0°C to -100.1°C ±(0.1% of rdg + 1.0°C) |
Temperature Coefficient | ± (0.015% of rdg +0.06°C)/°C |
Approx. Measurement Interval | 2 sec |
Data Storage | Capable of storing up to 10 measured data items |
Simplified Correction | Correction range: ±20°C of measured value |
Display Item | HOLD, RCD, REL, ADJ, MAX, MIN, MEM, °C chA, chB, chA-chB TC type K, J, E, T Battery alarm |
Other Functions | Auto power-off, battery alarm |
Display | LCD |
Operating Temperature | 0 to 50 ºC |
Humidity | 80% RH (no condensation) |
Power Requirements | Two AA-size alkaline dry batteries (LR6) |
Battery Life | About 450 hours |
Drip-proof Construction | Conforms to IP54 (dust-proof and drip-proof requirements of IEC529) |
Compliance with Standards | EMC Standards EMI (interference signal): EN55011;1998, EN61326-1;1998+A1 (Class B, Group 1) EMS (immunity): EN50082-1;1997, EN61326;1998+A1 |
Approx. Height | 151 mm |
Approx. Width | 56 mm |
Approx. Depth | 33 mm |
Approx. External Weight | 180 g |
Supplied Accessories | Two AA-size alkaline dry batteries (LR6) and instruction manual |
Optional Accessories | Extension Cable 5 m (2459 21)/10 m (2459 22) Soft case (930 12) Temperature Probes (for K type thermocouple) Rounded end probe (900 20B, 900 21B, 900 22B) Needle probe (900 23B, 900 24B) Surface probe (900 30B, 900 31B, 900 32B, 900 33B) Bead TC (2459 07) Waterproof Cover (5-per package) (930 11) |
Applications
- Temperature management in a refrigerated warehouse
- Temperature checks in equipment maintenance
- Temperature management for research and development
Features
- Memory-in Function
Up to ten data items can be stored. When recalled, the stored data value is displayed with its memory number. - User calibration function
Calibration and adjustment can be mode easily by operating the panel keys on instrument and a measurement-standard. - Thermocouple type (K, J, E, and T) select key
- Input channel select key
With each press, the channel switches through the sequence of "chA," "chB," and then "chA-chB." - Data hold key
A held measured value, can be stored in the memory of an optional memory number, which is selected with the up, down keys. - Maximum and minimum record key
Stores the maximum and minimum values from the time the RECORD key is pressed. - Data record key
Stores the held measured value in memory. (Up to ten) - Resolution select key
With each press, resolution alternates between 0.1ºC and 1ºC. (Within the range of -200.0ºC to 199.9ºC) - Maximum and minimum values, and stored data read key
Every time this key is pressed, the maximum and minimum values, stored data, and the current measured data are displayed in sequence. - Relative display select key
Displays measured values with reference to the value obtained immediately before this key was pressed (relative value). Each press of this key can select or release the relative display. - Simplified correction mode key
Sets the correction value, and selects active/inactive of the simplified correction function. - Data call-up key
Used to select a memory number when calling up stored data. Also used to adjust the correction value for simplified correction mode.
0 Reviews Hide Reviews Show Reviews
Yokogawa
Yokogawa 99009 K-Shaped Connector for TX10
MSRP:
Now:
$30.00
Was:
How to Order
Each item selected MUST be ordered as a separate line item.
Product NotesYokogawa 99009 K-Shaped Connector for TX10Product Features: K-Shaped Connector For use with TX10 K-Shaped...
Add to Cart
The item has been added
Yokogawa
Yokogawa 99008 U-Shaped Connector for TX10
MSRP:
Now:
$30.00
Was:
How to Order
Each item selected MUST be ordered as a separate line item.
Product NotesYokogawa 99008 U-Shaped Connector for TX10Yokogawa 99008 U-Shaped Connector Product Features: U-Shaped...
Add to Cart
The item has been added
Yokogawa
Yokogawa TX1001 1-Channel Single-Function Digital Thermometer
MSRP:
Now:
$210.00
Was:
How to Order
Each item selected MUST be ordered as a separate line item.
Product NotesYokogawa TX1001 1-Channel Single-Function Digital ThermometerProduct Features: TC Type: Select the thermocouple...
Add to Cart
The item has been added
Yokogawa
Yokogawa TX1002 1-Channel Multi-Function Digital Thermometer
MSRP:
Now:
$230.00
Was:
How to Order
Each item selected MUST be ordered as a separate line item.
Product NotesYokogawa TX1002 1-Channel Multi-Function Digital ThermometerProduct Features: Memory-in Function: Up to ten...
Add to Cart
The item has been added
Yokogawa
Yokogawa 93012 Soft Carrying Case for TX10 and TM20
MSRP:
Now:
$40.00
Was:
How to Order
Each item selected MUST be ordered as a separate line item.
Product NotesYokogawa 93012 Soft Carrying Case for TX10 and TM20Yokogawa 3012 Soft Case TX10 / TM20 Part...
Add to Cart
The item has been added
Yokogawa
Yokogawa 90024B TC-K Needle Temperature Probe for TX10, -50 to 600 °C
MSRP:
Now:
$235.00
Was:
How to Order
Each item selected MUST be ordered as a separate line item.
Product NotesYokogawa 90024B TC-K Needle Temperature Probe for TX10, -50 to 600 °CYokogawa 90024B TC-K Needle Temperature...
Add to Cart
The item has been added
Yokogawa
Yokogawa 90030B TC-K Surface Straight Temperature Probe for TX10, -20 to 250 °C
MSRP:
Now:
$330.00
Was:
How to Order
Each item selected MUST be ordered as a separate line item.
Product NotesYokogawa 90030B TC-K Surface Straight Temperature Probe for TX10, -20 to 250 °CProduct Features: TC-K Surface...
Add to Cart
The item has been added
Yokogawa
Yokogawa 90020B TC-K Rounded End Temperature Probe for TX10, -50 to 600 °C
MSRP:
Now:
$178.11
Was:
Yokogawa 90020B TC-K Rounded End Temperature Probe for TX10, -50 to 600 °CYokogawa 90020 TC-K Temperature Probe Product Features: TC-K Rounded End Temperature Probe, -50 to 600 °C For...
Add to Cart
The item has been added
Yokogawa
Yokogawa 90031B TC-K Surface Angled Temperature Probe for TX10, -20 to 250 °C
MSRP:
Now:
$340.00
Was:
How to Order
Each item selected MUST be ordered as a separate line item.
Product NotesYokogawa 90031B TC-K Surface Angled Temperature Probe for TX10, -20 to 250 °CYokogawa 90031B TC-K Surface Angled...
Add to Cart
The item has been added