OPTO 22 - GRV-ODCIS-12 _ DC digital output, 12 channels, 5-60 VDC, channel-to-channel isolation, on/off only
$265.00
- Brand
- OPTO 22
- SKU:
- GRV-ODCIS-12
OPTO 22 - GRV-ODCIS-12 _ DC digital output, 12 channels, 5-60 VDC, channel-to-channel isolation, on/off only
Quick Specs:
- DC digital output
- 12 channels
- 5-60 VDC
- channel-to-channel isolation
- on/off only
The GRV-ODCIS-12 digital DC output module provides 12 isolated channels of 5 - 60 VDC output, each switching a separate DC load. The module features channel-specific LEDs for troubleshooting. This module provides on/off switching only, offering a lower-cost option for projects with simple requirements.
The GRV-ODCIS-12 is part of the groov EPIC® system. It mounts on a groov EPIC chassis together with other discrete, analog, and serial groov I/O modules and a GRV-EPIC-PR1 processor.
NOTE: If your project needs more than just on/off switching, see the GRV-ODCI-12 module, which includes totalizing, pulsing, and other features.
The GRV-ODCIS-12 is part of the groov EPIC® system. It mounts on a groov EPIC chassis together with other discrete, analog, and serial groov I/O modules and a GRV-EPIC-PR1 processor.
NOTE: If your project needs more than just on/off switching, see the GRV-ODCI-12 module, which includes totalizing, pulsing, and other features.
Specifications:
| Feature | GRV-ODCI-12 | GRV-ODCIS-12 |
| Number of channels | 12 | 12 |
| Channel-to-channel isolation | x | x |
| On/off state | x | x |
| On/off totalization | x | |
| Output pulsing/TPO | x |
| Specification | GRV-ODCI-12 | GRV-ODCIS-12 | ||
| Line Voltage Range (nominal) | 5 - 48 VDC | 5 - 48 VDC | ||
| Line Voltage Range (max) | 5 - 60 VDC | 5 - 60 VDC | ||
| Current Rating | 400 mA per channel or 4.8 A per module (70 °C) | 400 mA per channel or 4.8 A per module (70 °C) | ||
| Surge Current | 5 A peak for 1 second | 5 A peak for 1 second | ||
| Recommended Max. Fuse (fast) or Circuit Breaker | 3 A 60 VDC / channel, 6 A 60 VDC / module | 3 A 60 VDC / channel, 6 A 60 VDC / module | ||
| Minimum Load | 20 mA | 20 mA | ||
| Output Voltage Drop | 1.2 V max. | 1.2 V max. | ||
| Off-State Leakage | 1 mA at 60 V | 1 mA at 60 V | ||
| Peak Blocking Voltage | 60 V | 60 V | ||
| TPO Period (min, max, resolution) | 0.005 seconds, 429496.72 seconds, 0.001 seconds | N/A | ||
| Turn On / Off Time | 2.5 ms | |||
| Isolation (field-to-logic) | 300 V working, 1500 V transient (1 minute) | 300 V working, 1500 V transient (1 minute) | ||
| Isolation (channel-to-channel) | 300 V working, 1500 V transient (1 minute) | 300 V working, 1500 V transient (1 minute) | ||
| Number of Channels | 12 | 12 | ||
| Chassis Power Consumption | 1.2 W | 1.2 W | ||
| Minimum GRV-EPIC-PR1 Firmware Version | 1.0.0 | 1.0.0 | ||
| Minimum PAC Project Version | 10.0000 | 10.0000 | ||
| Minimum Library Package for CODESYS Version | 1.0.0.0 | 1.0.0.0 | ||
| Wire Size | 28 - 14 AWG | 28 - 14 AWG | ||
| Torque, connector screw | 2.5 in-lb (0.28 N-m) | 2.5 in-lb (0.28 N-m) | ||
| Torque, hold-down screw | 3.5 in-lb (0.4 N-m) | 3.5 in-lb (0.4 N-m) | ||
| Temperature (operating) | -20 °C to +70 °C | -20 °C to +70 °C | ||
| Temperature (storage) | -40 °C to +85 °C | -40 °C to +85 °C | ||
| Relative Humidity (non-condensing) | 5 - 95% | 5 - 95% | ||
| Agency Approvals | UL/cUL (Class 1 Div. 2)a; CE, ATEX (Category 3, Zone 2), RoHS; DFARS; CB Scheme; UKCA | |||
| Warranty | Lifetime | |||
| a For use in hazardous locations, equipment must be mounted in an enclosure that meets the requirements of the National Electrical Code, ANSI/NFPA 70, and ANSI/ISA-61010-1 (82.02.01). | ||||