OPTO 22 - GRV-OAC-12 _ AC digital output, 12 channels, 12-250 VAC
Write a Review
Write a Review
OPTO 22
OPTO 22 - GRV-OAC-12 _ AC digital output, 12 channels, 12-250 VAC
MSRP:
Now:
$465.00
Was:
(You save
)
- Brand
- OPTO 22
- SKU:
- GRV-OAC-12
- UPC:
OPTO 22 - GRV-OAC-12 _ AC digital output, 12 channels, 12-250 VAC
Quick Specs:
- AC digital output
- 12 channels
- 12-250 VAC
OPTO 22 - GRV-OAC-12 _ AC digital output, 12 channels, 12-250 VAC
Quick Specs:
- AC digital output
- 12 channels
- 12-250 VAC
The GRV-OAC-12 digital output module can switch up to 12 separate AC loads of 12-250 VAC each. The module is part of the groov EPIC® system and provides 300 volts of transient protection for sensitive control electronics from industrial field signals. AC outputs are zero voltage turn on and zero current turn off to minimize transients during switching.
The GRV-OAC-12 offers a full set of features, including:
NOTE: For projects with simple requirements, the lower-cost GRV-OACS-12 offers on and off switching only.
The GRV-OAC-12 offers a full set of features, including:
- On/off state
- Output pulsing/TPO
- On/off totalization
- Open circuit indication
NOTE: For projects with simple requirements, the lower-cost GRV-OACS-12 offers on and off switching only.
Specifications:
Feature | GRV-OACI-12 | GRV-OACIS-12 | GRV-OAC-12 | GRV-OACS-12 |
Number of channels | 12 | 12 | 12 | 12 |
Channel-to-channel isolation | x | x | ||
On/off state | x | x | x | x |
Output pulsing/TPO | x | x | ||
On/off totalization | x | x | ||
Problem indication | x | x |
Specification | GRV-OACI-12 | GRV-OACIS-12 | GRV-OAC-12 | GRV-OACS-12 |
Line Voltage | 12 - 250 VAC | 12 - 250 VAC | 12 - 250 VAC | 12 - 250 VAC |
Current Rating (per channel) | 0.5 A | 0.5 A | 0.5 A | 0.5 A |
Recommended Max. Fuse (fast) or Circuit Breaker | 2 A 250 VAC / channel, 6 A 250 VAC common | 2 A 250 VAC / channel, 6 A 250 VAC common | 2 A 250 VAC / channel, 6 A 250 VAC common | 2 A 250 VAC / channel, 6 A 250 VAC common |
Minimum Load Current | 20 mA | 20 mA | 20 mA | 20 mA |
Output Voltage Drop | 1 V | 1 V | 1 V | 1 V |
Off-state Leakage at Nominal Voltage - 60 Hz | 1.25 mA @240 VAC 0.7 mA @120 VAC | 1.25 mA @240 VAC 0.7 mA @120 VAC | 1.25 mA @240 VAC 0.7 mA @120 VAC | 1.25 mA @240 VAC 0.7 mA @120 VAC |
Peak Blocking Voltage | 500 V | 500 V | 500 V | 500 V |
Operating Frequency | 40 to 60 Hz, 400 Hz | 40 to 60 Hz, 400 Hz | 40 to 60 Hz, 400 Hz | 40 to 60 Hz, 400 Hz |
Turn-on Time | ¤ 1/2 cycle (zero crossing) | ¤ 1/2 cycle (zero crossing) | ¤ 1/2 cycle (zero crossing) | ¤ 1/2 cycle (zero crossing) |
Turn-off Time | ¤ 1/2 cycle (zero crossing) | ¤ 1/2 cycle (zero crossing) | ¤ 1/2 cycle (zero crossing) | ¤ 1/2 cycle (zero crossing) |
TPO Period (min, max, resolution) | 0.1 seconds, 429496.7296 seconds, 0.001 seconds | N/A | 0.1 seconds, 429496.7296 seconds, 0.001 seconds | N/A |
Problem Indication | open circuit | none | open circuit | none |
Isolation (field-to-logic) | 300 V working, 1500 V transient (1 minute) | 300 V working, 1500 V transient (1 minute) | 300 V working, 1500 V transient (1 minute) | 300 V working, 1500 V transient (1 minute) |
Isolation (channel-to-channel) | 300 V working | 300 V working | NONE | NONE |
Number of Channels | 12 | 12 | 12 | 12 |
Chassis Power Consumption | 1.3 W | 1.3 W | 1.3 W | 1.3 W |
Minimum GRV-EPIC-PR1 Firmware Version | 1.0.0 | 1.0.0 | 1.0.0 | 1.0.0 |
Minimum PAC Project Version | 10.0000 | 10.0000 | 10.0000 | 10.0000 |
Minimum Library Package for CODESYS Version | 1.0.0.0 | 1.0.0.0 | 1.0.0.0 | 1.0.0.0 |
Wire Size | 28 - 14 AWG | 28 - 14 AWG | 28 - 14 AWG | 28 - 14 AWG |
Torque, connector screw | 2.5 in-lb (0.28 N-m) | 2.5 in-lb (0.28 N-m) | 2.5 in-lb (0.28 N-m) | 2.5 in-lb (0.28 N-m) |
Torque, hold-down screw | 3.5 in-lb (0.4 N-m) | 3.5 in-lb (0.4 N-m) | 3.5 in-lb (0.4 N-m) | 3.5 in-lb (0.4 N-m) |
Temperature (operating) | -20 °C to +70 °C | -20 °C to +70 °C | -20 °C to +70 °C | -20 °C to +70 °C |
Temperature (storage) | -40 °C to +85 °C | -40 °C to +85 °C | -40 °C to +85 °C | -40 °C to +85 °C |
Relative Humidity (non-condensing) | 5 - 95% | 5 - 95% | 5 - 95% | 5 - 95% |
Agency Approvals | UL/cUL(Class 1 Div. 2)a; CE, ATEX (Category 3, Zone 2), RoHS; DFARS; CB Scheme; UKCA | |||
Warranty | Lifetime | |||
a For use in hazardous locations, equipment must be mounted in an enclosure that meets the requirements of the National Electrical Code, ANSI/NFPA 70, and ANSI/ISA-61010-1 (82.02.01). |
0 Reviews Hide Reviews Show Reviews
OPTO 22
OPTO 22 - GRV-OACS-12 _ AC digital output, 12 channels, 12-250 VAC, on/off only
MSRP:
Now:
$400.00
Was:
OPTO 22 - GRV-OACS-12 _ AC digital output, 12 channels, 12-250 VAC, on/off onlyQuick Specs:AC digital output 12 channels 12-250 VAC on/off only The GRV-OACS-12 digital output...
Add to Cart
The item has been added
OPTO 22
OPTO 22 - GRV-OACI-12 _ AC digital output, 12 channels, 12-250 VAC, channel-to-channel isolation
MSRP:
Now:
$495.00
Was:
OPTO 22 - GRV-OACI-12 _ AC digital output, 12 channels, 12-250 VAC, channel-to-channel isolationQuick Specs:AC digital output 12 channels 12-250 VAC channel-to-channel isolation ...
Add to Cart
The item has been added
OPTO 22
OPTO 22 - GRV-OACIS-12 _ AC digital output, 12 channels, 12-250 VAC, channel-to-channel isolation, on/off only
MSRP:
Now:
$430.00
Was:
OPTO 22 - GRV-OACIS-12 _ AC digital output, 12 channels, 12-250 VAC, channel-to-channel isolation, on/off onlyQuick Specs:AC digital output 12 channels 12-250 VAC channel-to-channel isolation on/off...
Add to Cart
The item has been added
OPTO 22
OPTO 22 - GRV-IACI-12 _ AC digital input, 12 channels, 85-140 VAC, channel-to-channel isolation
MSRP:
Now:
$380.00
Was:
OPTO 22 - GRV-IACI-12 _ AC digital input, 12 channels, 85-140 VAC, channel-to-channel isolationQuick Specs:AC digital input 12 channels 85-140 VAC channel-to-channel isolation ...
Add to Cart
The item has been added
OPTO 22
OPTO 22 - GRV-IACIHV-12 _ AC input, 12 channels, 180-280 VAC, channel-to-channel isolation
MSRP:
Now:
$380.00
Was:
OPTO 22 - GRV-IACIHV-12 _ AC input, 12 channels, 180-280 VAC, channel-to-channel isolationQuick Specs:AC input 12 channels 180-280 VAC channel-to-channel isolation The...
Add to Cart
The item has been added
OPTO 22
OPTO 22 - GRV-IACIS-12 _ AC digital input, 12 channels, 85-140 VAC, channel-to-channel isolation, on/off state only
MSRP:
Now:
$300.00
Was:
OPTO 22 - GRV-IACIS-12 _ AC digital input, 12 channels, 85-140 VAC, channel-to-channel isolation, on/off state onlyQuick Specs:AC digital input 12 channels 85-140 VAC channel-to-channel isolation...
Add to Cart
The item has been added
OPTO 22
OPTO 22 - GRV-ODCI-12 _ DC digital output, 12 channels, 5-60 VDC, channel-to-channel isolation
MSRP:
Now:
$385.00
Was:
OPTO 22 - GRV-ODCI-12 _ DC digital output, 12 channels, 5-60 VDC, channel-to-channel isolationQuick Specs:DC digital output 12 channels 5-60 VDC channel-to-channel isolation Part...
Add to Cart
The item has been added
OPTO 22
OPTO 22 - GRV-IACIHVS-12 _ AC input, 12 channels, 180-280 VAC, channel-to-channel isolation, on/off state only
MSRP:
Now:
$300.00
Was:
OPTO 22 - GRV-IACIHVS-12 _ AC input, 12 channels, 180-280 VAC, channel-to-channel isolation, on/off state onlyQuick Specs:AC input 12 channels 180-280 VAC channel-to-channel isolation on/off state...
Add to Cart
The item has been added
OPTO 22
OPTO 22 - GRV-ODCIS-12 _ DC digital output, 12 channels, 5-60 VDC, channel-to-channel isolation, on/off only
MSRP:
Now:
$325.00