EI Capacitor Trip Device CTD-4 240V Specifications: Normal Input Voltage: 240 VAC Max. Input Voltage: 280 VAC Frequency: DC to 400 Hz Available Energy: 57 Joules Trip Capacitor fully charged at Normal Input Voltage: +/-20% @ 25 Deg. C Normal Output Voltage: 338 Volts DC Approx. Charge Time to 90% @ 25C: 570mS Capacitance: 990 uF +/-20% @ Deg C Temp. Influence on Capacitor: -10% @ -30 Deg. C/ +5% @60 Deg. C Ambient Operating Temperature: -30 Deg. C to 60 Deg. c Ambient Storage Temperature: -50 Deg. C to 80 Deg. C Short Circuit Protection: Continuous Mounting: Vertical or Horizontal Input Transient Protection: MOV protected to 65 joules single pulse transient