43 wire loop powered 4 20 mA transmitter Ranges and Resolution See table below. Select range and default engineering units. Consult factory for special engineering units. Units
43 wire loop powered 4 20 mA transmitter Ranges and Resolution See table below. Select range and default engineering units. Consult factory for special engineering units. Units may be changed to any listed under the same sensor range. Resolution is fixed and limited to available display digits. Accuracy Accuracy includes linearity, hysteresis, repeatability Standard accuracy: ±0.25% of full scale ±1 least significant digit HA accuracy option: ±0.1% FS ±1 LSD, see ranges for availability Sensor hysteresis: ±0.015% FS, included in accuracy Sensor repeatability:±0.01% FS, included in accuracy Display 3 readings per second nominal display update rate 4 digit LCD, 0.5" H and 5 character 0.25" H alphanumeric BL: Red LED backlight Batteries, Battery Life, Low Battery Indication 2 AA alkaline included B: Approx. 2000 hours BL: Approx. 150-1500 hours depending on backlight usage Low battery symbol on display Controls & Functions Front button turns gauge on or off, zeros gauge reference gauges, and cycles through min./max. functions Internal buttons for engineering unit selection, auto shutoff time, min/max setup, calibration. Pass code protected setup & calibration. BL: Front button activates backlighting for 1 minute Min./Max. Functions Minimum and maximum readings stored 3 times per second Front button cycles through min. display, max. display, clear Configurable for min. only, max. only, min./max., or none Configure to clear or retain min./max. values at power off
Cecomp CCConformal coating on circuit boardsFor high humidity applicationsMust be factory installedFor any Cecomp modelStandard on DPG2000 and CTPB series
Cecomp WMPSKThe optional power supply kit includes a 115 VAC (50/60 Hz) wall-mount power supply with U.S. style 2-prong plug. Output is 12 VDC at 200 mA. Power supply is UL and CSA listed. The...
CECOMP F4B1BARA1.000 bar absolute to 0Ranges and Resolution See table below. Select range and default engineering units. Consult factory for special engineering units. Units may be changed to any...
CECOMP F16BNBL760TORRA760.0 torr absolute to 0Ranges and Resolution See table below. Select range and default engineering units. Consult factory for special engineering units. Units may be changed to...
CECOMP DSGL115N42 wire loop powered 4 20 mA transmitter Ranges and Resolution See table below. Select range and default engineering units. Consult factory for special engineering units. Units may be...
Cecomp -ASF Ranges from ±0.25 inH2O to 100 inH2O Positive or Zero-Center Ranges Mounts in Industry-Standard Openings ±2% Accuracy Die Cast Aluminum Housing
Cecomp HAHigh accuracy, ±0.1%FS, ±1LSD. A high accuracy transducer is selected and linearized to give ±0.1% FS ±1 LSD accuracy when this option is ordered. This makes the gauge ideal for use as a...