Metal front cover. Not for NEMA 4X models. Calibration data, 5 test points, test date Accuracy Accuracy includes linearity, hysteresis, repeatability Standard accuracy: ±0.25%
Metal front cover. Not for NEMA 4X models. Calibration data, 5 test points, test date Accuracy Accuracy includes linearity, hysteresis, repeatability Standard accuracy: ±0.25% of full scale ±1 least significant digit HA accuracy option: ±0.1% FS ±1 LSD, see ranges for availability Sensor hysteresis: ±0.015% FS, included in accuracy Sensor repeatability:±0.01% FS, included in accuracy Display 3 readings per second nominal display update rate Ranges to 2000: 3.5 digit (1999) LCD, 0.5" H digits Ranges >2000: 4 digit LCD, 0.5" H digits, 5 character 0.25" H alphanumeric lower display BL models: Red LED display backlight Batteries, Low Battery Indication, Battery Life Two AA alkaline included Low battery indication on display (battery life is approximate) B ranges to 2000: 2500 hours B ranges >2000: 2000 hours BBL ranges to 2000: 180 hours BBL ranges >2000: 150 to 1500 hours Controls B ranges to 2000: Front button turns gauge on/off, starts auto shutoff timer BL ranges to 2000: Front button turns gauge on/off, starts auto shutoff timer, backlight is on when gauge is on. B ranges >2000: Front button turns gauge on/off, starts auto shutoff timer, zeros display (gauge ref. only) BL ranges >2000: Front button turns gauge on/off, starts auto shutoff timer, activates backlighting for one minute, zeros display (gauge ref. only) Auto Shutoff Factory set to 5, 10, 30 minutes, or on/off Ranges >2000 can be factory set to custom minutes or hours Calibration Ranges to 2000: Front calibration potentiometers, non-interactive zero and span, ±10% range Ranges >2000: Internal calibration buttons, non-interactive zero, span, and linearity, ±10% of range
Cecomp MCMetal gauge bezel (front cover)Gray epoxy coated metal front gauge bezelImproves chemical resistance when exposed to synthetic oils and hydraulic fluidsStandard on DPG2000 and CTPB seriesNOT...
CECOMP DSGL320N39 wire loop powered 4 20 mA transmitter Ranges and Resolution See table below. Select range and default engineering units. Consult factory for special engineering units. Units may be...
CECOMP DSGA415N40 wire loop powered 4 20 mA transmitter Ranges and Resolution See table below. Select range and default engineering units. Consult factory for special engineering units. Units may be...
CECOMP DSGB320N37 wire loop powered 4 20 mA transmitter Ranges and Resolution See table below. Select range and default engineering units. Consult factory for special engineering units. Units may be...
CECOMP C4100Program to Measure Flow and Velocity LED Pressure Level Indicator and OLED Display Ranges from ±0.25 inH2O to ±40 inH2O Accuracies of ±0.25%, ±0.5%, or ±1% Mounts in Industry-Standard...