Absolute Process Instruments API 1700 G _ Frequency input single alarm
Write a Review
Absolute Process Instruments
Absolute Process Instruments API 1700 G _ Frequency input single alarm
- Brand
- Absolute Process Instruments
- SKU:
- API 1700 G
- UPC:
Absolute Process Instruments API 1700 G _ Frequency input single alarm
Features with all optional accessories:
<Absolute Process Instruments API 1700 G _ Frequency input single alarm
Features with all optional accessories:
- Accepts Most Types of Pulse Signals
- Field Adjustable Trip and Reset
- Plug-In Design for Fast Installation
- Input LoopTracker® and Alarm Status LEDs
- Alarm Test, Optional Reset Button
Applications:
- Machinery Speed Alarm
- Redundant or Backup Alarm
- Conveyor or Machine Malfunction Alarm
The API 1700 G are factory configured for a frequency input and provide alarm contact outputs. Heavy duty relay contacts allow the module to directly control high capacity loads.
The API 1700 G provides a single set point and reset point adjustment and DPDT relay contacts. The alarm output can be factory configured for HI or LO operation, non-latching or latching, normal or reverse acting. Top-accessible potentiometers are used to adjust the alarm trip and reset points.
LoopTracker and Alarm Status LEDs
API exclusive features include a LoopTracker LED that varies in intensity with changes in the frequency input signal. A red/green bi-color alarm status LED visually indicate alarm status. These LEDs provide a quick visual picture of your process at all times.
Output Test/Reset
API's exclusive functional test button can be used to verify the alarm and system operation. The output test button greatly aids in saving time during initial startup and/or troubleshooting. The HT latching option provides the additional function of unlatching the alarm when the reset button is pressed. The alarm will reset if the alarm condition not longer exists.
Specifications Table:
Input | 0-10 Hz to 0-30 kHz |
Output | One 8 Amp DPDT Relay or Two 8 Amp SPDT Relays |
Frequency Input Range | Factory configured, please specify frequency range
|
Input Type |
|
Input Amplitude | 100 mVRMS to 150 VRMS |
Input Impedance |
|
Sensitivity/Hysteresis | Single-turn potentiometer for sensitivity adjustment
|
Input Protection |
|
Relay Output | Two SPDT form C contact sets operating in unison as one DPDT contact set:
|
Relay Contact Rating |
|
Deadband | 0.02% of input frequency span when reset point adjustment is not in use |
Output Test Button | Toggles relay(s) to opposite state when pressed |
Response Time | 70 milliseconds typical |
Ambient Temperature Range and Stability |
|
Housing |
|
Sockets | Socket mounts to 35 mm DIN rail or can be surface mounted |
Power | 115 VAC ±10%, 50/60 Hz, 2.5 W max |
0 Reviews Hide Reviews Show Reviews
Absolute Process Instruments
Absolute Process Instruments API 1700 G A230 _ Frequency input single alarm
Absolute Process Instruments
Absolute Process Instruments API 1700 G D _ Frequency input single alarm
Absolute Process Instruments
Absolute Process Instruments API 1700 G P _ Frequency input single alarm
Absolute Process Instruments
Absolute Process Instruments APD 1700 _ Frequency input single alarm
Absolute Process Instruments
Absolute Process Instruments APD 1700 D _ Frequency input single alarm
Absolute Process Instruments
Absolute Process Instruments API 1400 G _ RTD input single alarm
Absolute Process Instruments
Absolute Process Instruments API 1600 G _ AC input single alarm
Absolute Process Instruments
Absolute Process Instruments API 1080 G _ DC input single alarm. Isolated input.
Absolute Process Instruments