Absolute Process Instruments APD 6010 _ AC to DC transmitter up to 5 A input. Fully isolated.
Write a Review
Absolute Process Instruments
Absolute Process Instruments APD 6010 _ AC to DC transmitter up to 5 A input. Fully isolated.
- Brand
- Absolute Process Instruments
- SKU:
- APD 6010
- UPC:
Absolute Process Instruments APD 6010 _ AC to DC transmitter up to 5 A input. Fully isolated.
Cecomp Electronics, APD 6010, A
Absolute Process Instruments APD 6010 _ AC to DC transmitter up to 5 A input. Fully isolated.
Cecomp Electronics, APD 6010, AC to DC Isolated Signal Conditioner, 85-265 VAC, 60-300 VDC Power
Features:
- Full 1200 V Input/Output/Power Isolation
- Zero and Span Output Calibration Potentiometers
- Input and Output LoopTracker® LEDs
- Functional Test Button with Remote Capability
- Built-In Loop Power Supply for Sink/Source Output
Applications:
- SConvert an AC Signal to a DC Process Signal
- Monitor Voltage Ranges
- Convert, Amplify Low Level AC Signals
The APD 6010 accepts an AC voltage or current input and provides an optically isolated DC voltage or current output that is linearly related to the input. Typical applications include monitoring line, power supply, shunt, and motor voltages or current (either directly or with a current transducer) for control, preventive maintenance, etc.
The full 3-way (input, output, power) isolation makes this module useful for ground loop elimination or noise pickup reduction. The APD 6010 is factory configured to customer requirements. Consult the factory for assistance with special ranges.
Sink/Source Output Versatility
For maximum versatility a milliamp output can be selectively wired for sinking or sourcing. This allows the APD 6010 milliamp output to connect to a powered or unpowered current loop. The 20 VDC output loop supply can be used to power a passive mA device if required.
LoopTracker
API exclusive features include two LoopTracker LEDs (green for input, red for output) that vary in intensity with changes in the process input and output signals. These provide a quick visual picture of your process loop at all times and can greatly aid in saving time during initial startup and/or troubleshooting.
Functional Test
An API exclusive feature includes the Functional Test Button to provide a fixed output (independent of the input) when held depressed. The test output level is potentiometer adjustable from 0 to 100% of output span.
The functional test button greatly aids in saving time during initial startup and/or troubleshooting. The functional test can also be enabled with a customersupplied external contact closure across terminals 5 and 6. This allows remote testing of the output or, for example, a PLC-controlled manual override setting
Specifications Table:
Input | True RMS 0-50 mVAC to 0-300 VAC, 0-1 mAAC to 0-1000 mAAC. Factory configuredspecify mVAC, VAC, or mAAC range. |
Output | 0-1 V to 0-10 VDC, ±5 VDC, ±10 VDC, 0-1 mA to 0-20 mADC, 4-20 mADC. Factory configuredspecify VDC or mADC range. |
AC Input Range | Factory configured, please specify input range. Consult factory for special ranges
|
Input Impedance (Voltage Input) | 220 kΩ minimum |
Input Voltage Burden (Current Input) | 1.0 VRMS maximum |
Input Frequency | 40 Hz to 1000 Hz sinusoidal |
Input Protection, Common Mode | 750 VDC or 750 VACp |
Common Mode Rejection | 120 dB minimum |
DC Output Ranges | Factory configured, please specify input range. Consult factory for special ranges
|
Output Calibration | Multi-turn zero and span potentiometers (±15% of span adjustment range typical) |
Output Loop Power Supply |
|
Output Test/Override | Front momentary button or external contact closure sets output to test level. Potentiometer adjustable 0-100% of span. |
Output Ripple and Noise | Less than 10 mVRMS at 40 Hz and above |
Linearity | Better than ±0.1% of span |
Ambient Temperature Range and Stability |
|
Response Time | 150 milliseconds nominal (0-90%) |
Isolation |
|
Housing |
|
Connectors | Four 4-terminal removable connectors, 14 AWG max wire size |
Power | 85-265 VAC, 50/60 Hz or 60-300 VDC, 2 W maximum |
0 Reviews Hide Reviews Show Reviews
Absolute Process Instruments
Absolute Process Instruments APD 6010 D _ AC to DC transmitter up to 5 A input. Fully isolated.
Absolute Process Instruments
Absolute Process Instruments APD 6380 _ AC to DC transmitter. Fully isolated
Absolute Process Instruments
Absolute Process Instruments APD 5393 _ AC to DC transmitter. Fully isolated.
Absolute Process Instruments
Absolute Process Instruments APD 5393 D _ AC to DC transmitter. Fully isolated.
Absolute Process Instruments
Absolute Process Instruments APD 6380 D _ AC to DC transmitter-Fully isolated
Absolute Process Instruments
Absolute Process Instruments APD 4300 _ DC to DC transmitter. Fully isolated.
Absolute Process Instruments
Absolute Process Instruments APD 4003 _ Potentiometer input transmitter. Fully isolated.
Absolute Process Instruments
Absolute Process Instruments APD 4008 _ Potentiometer input transmitter. Fully isolated.
Absolute Process Instruments