AEMC 1954 has a resolution of 120 x 160, the advanced infrared thermography detection technology is used in sectors of industry as diverse as electrical maintenance, metallurgy and steel making, petroleum, automation, natural gas exploration, transportation as well as other professions. The wireless Bluetooth connection allows for the combination of electrical and physical measurements to the imaging data.
DESCRIPTION
Features:
- Focus free quality. Provides crisp, clear thermal and real images without the need for adjustments.
- Accurate temperate measurement over the full range. From -4 to 482°F (-20 to 250°C) with a stability of 80mK at 86°F (30°C)
- Audio narration can be recorded with thermograms. You can describe the circumstances of each image, providing additional text and description to be stored with each image.
- Automatic non-uniformity temperature correction. Compensates for any internal drift to improve accuracy.
- Measurement data can also be stored with each thermogram Both cameras can wirelessly connect via Bluetooth to compatible AEMC® test instruments and loggers, enabling you to combine electrical and physical measurements to the imaging data.
- Offers broad range of operational capabilities. Locating the cold and hot spots in the image, measuring the temperature of a selected point in the image, displaying the temperature profile of a line in the image, displaying points at the same temperature in the image, and freezing the colors representing the temperatures.
- CAmReport® software. Included for downloading stored files from the instrument to a computer for further processing, analysis, and report generation.
- This camera is built to last. Their rugged design survives if accidentally dropped on any of its surfaces from as high as 6'.
- Exceptionally long battery life. Ensures no loss of test time during a typical work day.
Applications:
- Preventative maintenance
- Analyzing old or new buildings
- Industrial maintenance
- Mechanical maintenance
- Search for water leaks in walls
- Detect embedded or blocked pipes
- Faulty electrical contacts
- Verification and inspection on parts on mechanical assemblies
SPECIFICATION
IR Detector | |
Type | UFPA microbolometer |
Spectral Range | 8 ~14 µm |
Resolution | 120 x 160 |
Imaging Performance | |
Sensitivity (N.E.T.D) | 80 mK @ 86°F (30°C) (0.08°C @ 30°C) |
Frequency | 9 Hz |
Field of View | 28° x 38° |
IFOV (Spatial Resolution) | 4.1 mrad |
Minimum Focal Distance | .98' (0.3m), fixed focus |
Environmental Specifications | |
Operating Temperature | -4 to 122°F (-15 to 50°C) |
Storage Temperature | -40 to 158°F (-40 to 70°C) |
Humidity | 10 to 95% |
Drop Resistance | 6' (2m) on all sides |