How to Order
Each item selected MUST be ordered as a separate line item. Product Notes All Clamp-on Meters include Test Leads (where applicable) and a carrying case. Temperature Measurement requires optional Probe 234901 (located under Digital Clamp-on Accessories) Product Notes
Yokogawa CL345 True-RMS Clamp-on Tester, Leakage Current, 400 A
- Leakage current measurement with current range from 40mA to 400A
- Manual range switching and auto power-off functions
- 40mm in diameter of measurable conductor
- True RMS display
- Auto power-off
- Manual range switching
- Approved for conformity to safety standards EN61010-2-032 (CAT. III 300 V)
Specifications:
| Description | AC LEAKAGE |
|---|---|
| Method of detection | True RMS |
| Display | LCD (Digital display: 4200 counts) |
| Response Time | Approx. 2 second |
| Range Switching | Manual-range |
| Data hold | On all range |
| Operating temperature and humidity | 0 - 40°C, 85% RH or less (no condensation) |
| Influence of external magnetic field | 10 mA or less in proximity to a 15 mm-dia conductor carrying 100A |
| Influence of conductor position | 40/400 mA range: Within 5 dgt at every part inside the jaw 400A range, 0 to 250A: Within ±0.5% rdg ±5 dgt at every part inside the jaw section |
| Influence of Residual Current | 12 mA or less in proximity to a 10 mm-dia conductor carrying 100A |
| Safety Standard | Conforms EN61010-1, EN61010-2-032 |
| Circuit voltage | 300 Vrms or less |
| Withstanding voltage | 3.7 kV AC for one minute |
| Power Supply | LR03 x 2 R0-3 (UM-4) x 2 |
| Battery Life | Approx. 24 hours (continuous) |
| Consumed current | Approx. 21 mA |
| Auto power-off | Approx. 10 minutes |
| Diameter of measurable conductor | 40 mm at maximum |
| Dimensions | Approx. 81 (W) x 185 (H) x 32 (D) mm |
| Weight | Approx. 270 g |
| Accessories | Batteries, carrying case (93030) User's manual (IM CL340) |
| Peak Hold | On all range |