Yokogawa 701917 - Current Probe 50 MHz / 5 ARMS
Write a Review
Yokogawa
Yokogawa 701917 - Current Probe 50 MHz / 5 ARMS
- Brand
- Yokogawa
- SKU:
- 701917
- UPC:
- Availability:
- Y
Yokogawa 701917 - Current Probe 50 MHz / 5 ARMS
Yokogawa 701917 - Current Probe 50 MHz / 5 ARMSYokogawa 701917 - Current Probe 50 MHz / 5 ARMS
Yokogawa 701917 - Current Probe 50 MHz / 5 ARMSWhat is the 701917 Current Probe?
701917 is a low noise compact current probe for measuring low-level currents from 1 mA to 5 A. Best suited for design and verification applications requiring high-sensitivity at low currents.
Frequency bandwidth: DC to 50 MHz
Maximum continuous input range: 5 Arms
Functions with Digital Oscilloscopes, ScopeCorders, and other waveform measuring instruments
Features:
- Bandwidth: DC to 50 MHz; current measurement: Max 5 Arms
- 10x more sensitive than previous models 701928/701929/701932/701933
- Low noise compact current probe for measuring low level currents from 1 mA to 5 A.
- Slim and light weight sensor head makes it easy to use in narrow spaces.
- Zero-adjustment can be done by simply pushing the button on the termination box.
- Demagnetization can also be done by holding down the DEMAG button for a quicker setup.
- Powered by the DLs probe power supply terminal.
- The probes are also compatible with the 701934 probe power supply.
- Current values can be read directly on DL series instruments. Using the current probe selection menu eliminates the need to enter current/voltage conversion values.
Overview:
How does a Current Probe Work?
Conductors' current flows cause electromagnetic flux fields. Oscilloscope current probes detect the fields' strength and convert it to voltage for an oscilloscope to measure for waveform analysis.
How to use a 701917 Current Probe
Before measuring, check that there are no problems with the instrument or the measurement target and that measurement preparations have been taken.
1. Pull the sensor opening lever to open the sensor head.
2. Align the direction of the arrow of the current direction mark indicated at the sensor tip to the direction of the measured current, and clamp so that the conductor is at the center of the sensor aperture. Low potential side (ground potential side) High potential side
3. Hold down the sensor opening lever until the JAW UNLOCKED indication disappears to lock the sensor head. The JAW UNLOCKED LED turns off.
4. You can observe the current waveform on the waveform measuring instrument. The output voltage rate of the 701917 and 701918 is 1 V/A. Convert the voltage sensitivity of the waveform measuring instrument to current sensitivity. For example, if the voltage sensitivity of the waveform measuring instrument is 10 mV/DIV, the current sensitivity is 10 mA/DIV.
0 Reviews Hide Reviews Show Reviews
Yokogawa
Yokogawa 701929 - Current Probe 50 MHz / 30 ARMS
Yokogawa
Yokogawa 701933 - Current Probe 50 MHz / 30 ARMS
Yokogawa
Yokogawa 702915 - Current Probe 50 MHz/ 0.5 ARMS, 5 ARMS, 30 ARMS
Yokogawa
Yokogawa 701918 - Current Probe 120 MHz / 5 ARMS
Yokogawa
Yokogawa 701931 - Current Probe 2 MHz / 500 ARMS - Current Probe For Oscilloscope
Yokogawa
Yokogawa 701928 - Current Probe 100 MHz / 30 ARMS - Scope Current Probe
Yokogawa
Yokogawa 702916 - Current Probe 120 MHz/ 0.5 ARMS, 5 ARMS, 30 ARMS
Yokogawa
Yokogawa 701932 - Current Probe 100 MHz / 30 ARMS
Yokogawa