In the totalizing batch mode, the secondary value (batch coun
In the totalizing batch mode, the secondary value (batch count) is incremented after the primary totalizing count has completed its cycle.
The counter is powered from 120 or 240VAC and has a non-volatile EEPROM to retain all programming and count information when the power source is removed or interrupted.
An option 12DCV excitation output module can provide power for external sensors.This versatile counter has latching, boundary or timed (0.01 to 599.99 seconds) output modes.
Features
Specifications:
| Display | |
| Type | 6-digit, 7-segment, red LED |
| Height | 0.56" (14.2mm) |
| Decimal Point | User-programmable |
| Count Direction | "+" indication implied, "-" indication displayed |
| Display Range | -99,999 to +999,999 |
| Output Indicators | 1 and 2 |
| Power Requirements | |
| AC Voltages | 120 or 240VAC, ±10% |
| Power Consumption | 3VA |
| Input Ratings | |
| Current Sinking | 10KΏ 5% Resistor pull-up to (9.0 - 16DCV) ±10% |
| Current Sourcing | 5.1KΏ 5% Resistor pull-down to common |
| Minimum Pulse Width | ~5μs |
| Other | |
| Low Pass Filter | < 200Hz |
| Low Bias | VLT = 1.6V ±10% VUT = 3.6V ±10% |
| High Bias | VLT = 5.0V ±10% VUT = 7.0V ±10% |
| Count Rate | 20KHz (Pulse Max) 5KHz (Quadrature X4 Max) |
| Maximum Voltage InputA,B, and User | 30DCV (Max) |
| User Input | VLT ≤ 0.9DCV, VUT = 3.15DCV (max) (Second channel reset) Count on the second channel is reset when the User Input is pulled low |