OPTO 22 - OPTOEMU-ACT-1250-600 _ Current transformer, split core, .333V, 600A, 2 inch ID
$92.50
- Brand
- OPTO 22
- SKU:
- OPTOEMU-ACT-1250-600
OPTO 22 - OPTOEMU-ACT-1250-600 _ Current transformer, split core, .333V, 600A, 2 inch ID
OPTO 22 - OPTOEMU-ACT-1250-600 _ Current transformer, split core, .333V, 600A, 2 inch IDQuick Specs:
- Current transformer
- split core
- .333V
- 600A
- 2 inch ID
The OPTOEMU-ACT-1250-600 split-core current transformer (CT) from Continental Control Systems offers an easy, safe, and inexpensive method for monitoring electrical energy usage.
Ideal for retrofit applications, the split core makes it possible to attach the CT without disturbing existing wiring. This CT swings open for one-handed operation. Just open it, slip it over the wire, and snap the CT closed. Once assembled, the CT has no exposed metal parts.
The 0.333 VAC output of this CT is low, making it much more safe to install and use than CTs with current secondaries. It is also less expensive.
ACT series CTs comply with the linearity and accuracy requirements of IEEE/ANSI C57.13 class 1.2 for tenant submetering and billing. They are UL Listed, certified by Underwriters Laboratory (UL) to meet the new 2017 NEC code requirement that CTs installed in the field must be UL 2808 Listed under category code XOBA.
This CT is recommended for use with the following Opto 22 products:
Ideal for retrofit applications, the split core makes it possible to attach the CT without disturbing existing wiring. This CT swings open for one-handed operation. Just open it, slip it over the wire, and snap the CT closed. Once assembled, the CT has no exposed metal parts.
The 0.333 VAC output of this CT is low, making it much more safe to install and use than CTs with current secondaries. It is also less expensive.
ACT series CTs comply with the linearity and accuracy requirements of IEEE/ANSI C57.13 class 1.2 for tenant submetering and billing. They are UL Listed, certified by Underwriters Laboratory (UL) to meet the new 2017 NEC code requirement that CTs installed in the field must be UL 2808 Listed under category code XOBA.
This CT is recommended for use with the following Opto 22 products:
- groov EPIC® power monitoring analog input module, part number GRV-IVAPM-3
- groov RIO® energy monitoring edge I/O module, part number GRV-R7-I1VAPM-3
- SNAP power monitoring analog input module, part number SNAP-AIPM-3V
- OptoEMU Sensor¢ power monitoring appliance, part number OPTOEMU-SNR-3V
- OPTOEMU-ACT-0750-050
- OPTOEMU-ACT-0750-100
- OPTOEMU-ACT-0750-250
- OPTOEMU-ACT-1250-250
- OPTOEMU-ACT-1250-400
Specifications:
Specification | OPTOEMU-ACT-1250-250 | OPTOEMU-ACT-1250-400 | OPTOEMU-ACT-1250-600 |
---|---|---|---|
Accuracy | 0.75% | 0.75% | 0.75% |
Rated Amps | 250 amps | 400 amps | 600 amps |
Accuracy Class | IEEE/ANSI C57.13, Class 1.2 | IEEE/ANSI C57.13, Class 1.2 | IEEE/ANSI C57.13, Class 1.2 |
CE Accuracy | IEC 60044-1, Class 1.0 | IEC 60044-1, Class 1.0 | IEC 60044-1, Class 1.0 |
Standard Lead Length | 8 ft (2.4 m), 18 AWG | 8 ft (2.4 m), 18 AWG | 8 ft (2.4 m), 18 AWG |
Phase Angle | ± 0.50 degrees | ± 0.50 degrees | ± 0.50 degrees |
Output Options | 0.333 VAC | 0.333 VAC | 0.333 VAC |
Operating Temperature | 30°C to 75°C | 30°C to 75°C | 30°C to 75°C |
Line Frequency | 50/60 Hz | 50/60 Hz | 50/60 Hz |
CE Safety | CE | CE | CE |
RoHS Compliance | Yes | Yes | Yes |
UL USA | UL Listed, XOBA,UL 2808 | UL Listed, XOBA,UL 2808 | UL Listed, XOBA,UL 2808 |
UL Canada | UL Listed - XOBA7 | UL Listed - XOBA7 | UL Listed - XOBA7 |
Warranty* | 5 years* | 5 years* | 5 years* |
* Original manufacturers warranty applies. See https://ctlsys.com/warranty-and-return-policy/ |