OPTO 22 - GRV-IACIHVS-12 _ AC input, 12 channels, 180-280 VAC, channel-to-channel isolation, on/off state only
Write a Review
Write a Review
OPTO 22
OPTO 22 - GRV-IACIHVS-12 _ AC input, 12 channels, 180-280 VAC, channel-to-channel isolation, on/off state only
MSRP:
Now:
$300.00
Was:
(You save
)
- Brand
- OPTO 22
- SKU:
- GRV-IACIHVS-12
- UPC:
OPTO 22 - GRV-IACIHVS-12 _ AC input, 12 channels, 180-280 VAC, channel-to-channel isolation, on/off state only
Quick Specs:
- AC input
- 12 channels
-
OPTO 22 - GRV-IACIHVS-12 _ AC input, 12 channels, 180-280 VAC, channel-to-channel isolation, on/off state only
Quick Specs:
- AC input
- 12 channels
- 180-280 VAC
- channel-to-channel isolation
- on/off state only
The GRV-IACIHVS-12 is part of the groov EPIC® system. This AC input module senses status from up to 12 devices such as pumps, fans, and motors that use a 180 - 280 VAC. All 12 channels on the module are isolated from each other (channel-to-channel isolation).
The GRV-IACIHVS-12 senses on and off status only.
The GRV-IACIHVS-12 mounts on a groov EPIC chassis with other discrete, analog, and serial groov I/O modules and a GRV-EPIC-PR1 processor.
NOTE: For projects with more complex requirements, see the GRV-IACIHV-12 module, which offers many additional features.
The GRV-IACIHVS-12 senses on and off status only.
The GRV-IACIHVS-12 mounts on a groov EPIC chassis with other discrete, analog, and serial groov I/O modules and a GRV-EPIC-PR1 processor.
NOTE: For projects with more complex requirements, see the GRV-IACIHV-12 module, which offers many additional features.
Specifications:
Feature | GRV-IACHV-24 | GRV-IACHVS-24 | GRV-IACIHV-12 | GRV-IACIHVS-12 |
Number of channels | 24 | 24 | 12 | 12 |
Channel-to-channel isolation | x | x | ||
On/off state | x | x | x | x |
On/off latching | x | x | ||
On/off totalization | x | x | ||
Frequency measurement | x | x | ||
Period measurement | x | x | ||
Pulse measurement | x | x |
Specification | GRV-IACHV-24 | GRV-IACHVS-24 | GRV-IACIHV-12 | GRV-IACIHVS-12 |
Nominal Input Voltage Range (RMS) | 180 - 280 VAC | 180 - 280 VAC | 180 - 280 VAC | 180 - 280 VAC |
Turn-on Voltage | 180 VAC | 180 VAC | 180 VAC | 180 VAC |
Turn-off Voltage | 35 VAC | 35 VAC | 35 VAC | 35 VAC |
Input Impedance (±5%) | 532 kOhms | 532 kOhms | 271 kOhms | 271 kOhms |
Operating Frequency | 40 Hz to 400 Hz | 40 Hz to 400 Hz | 40 Hz to 400 Hz | 40 Hz to 400 Hz |
Turn-on Time (typical) | 30 ms at V | 30 ms at V | 30 ms at V | 30 ms at V |
Turn-off Time (typical) | 30 ms at V | 30 ms at V | 30 ms at V | 30 ms at V |
Isolation (field-to-logic) | 300 VAC, 1500 V Transient | 300 VAC, 1500 V Transient | 300 VAC, 1500 V Transient | 300 VAC, 1500 V Transient |
Isolation (channel-to-channel) | N/A | N/A | 300 VAC working | 300 VAC working |
Number of Channels | 24 | 24 | 12 | 12 |
Chassis Power Consumption | 1.0 W | 1.0 W | 1.0 W | 1.0 W |
Wire Size | 28 - 14 AWG | 28 - 14 AWG | 28 - 14 AWG | 28 - 14 AWG |
Torque, connector screw | 2.5 in-lb (0.28 N-m) | 2.5 in-lb (0.28 N-m) | 2.5 in-lb (0.28 N-m) | 2.5 in-lb (0.28 N-m) |
Torque, hold-down screw | 3.5 in-lb (0.4 N-m) | 3.5 in-lb (0.4 N-m) | 3.5 in-lb (0.4 N-m) | 3.5 in-lb (0.4 N-m) |
Temperature (operating) | -20 °C to +70 °C | -20 °C to +70 °C | -20 °C to +70 °C | -20 °C to +70 °C |
Temperature (storage) | -40 °C to +85 °C | -40 °C to +85 °C | -40 °C to +85 °C | -40 °C to +85 °C |
Relative Humidity (non-condensing) | 5 - 95% | 5 - 95% | 5 - 95% | 5 - 95% |
Agency Approvals | UL/cUL (Class 1 Div. 2)a; CE, ATEX (Category 3, Zone 2), RoHS; DFARS; CB Scheme; UKCA | |||
Warranty | Lifetime | Lifetime | Lifetime | Lifetime |
a For use in hazardous locations, equipment must be mounted in an enclosure that meets the requirements of the National Electrical Code, ANSI/NFPA 70, and ANSI/ISA-61010-1 (82.02.01). | ||||
0 Reviews Hide Reviews Show Reviews
OPTO 22
OPTO 22 - GRV-IACIHV-12 _ AC input, 12 channels, 180-280 VAC, channel-to-channel isolation
MSRP:
Now:
$380.00
Was:
OPTO 22 - GRV-IACIHV-12 _ AC input, 12 channels, 180-280 VAC, channel-to-channel isolationQuick Specs:AC input 12 channels 180-280 VAC channel-to-channel isolation The...
Add to Cart
The item has been added
OPTO 22
OPTO 22 - GRV-IACIS-12 _ AC digital input, 12 channels, 85-140 VAC, channel-to-channel isolation, on/off state only
MSRP:
Now:
$300.00
Was:
OPTO 22 - GRV-IACIS-12 _ AC digital input, 12 channels, 85-140 VAC, channel-to-channel isolation, on/off state onlyQuick Specs:AC digital input 12 channels 85-140 VAC channel-to-channel isolation...
Add to Cart
The item has been added
OPTO 22
OPTO 22 - GRV-IACHVS-24 _ AC input, 24 channels, 180-280 VAC, on/off state only
MSRP:
Now:
$300.00
Was:
OPTO 22 - GRV-IACHVS-24 _ AC input, 24 channels, 180-280 VAC, on/off state onlyQuick Specs:AC input 24 channels 180-280 VAC on/off state only The GRV-IACHVS-24 digital input...
Add to Cart
The item has been added
OPTO 22
OPTO 22 - GRV-OACIS-12 _ AC digital output, 12 channels, 12-250 VAC, channel-to-channel isolation, on/off only
MSRP:
Now:
$430.00
Was:
OPTO 22 - GRV-OACIS-12 _ AC digital output, 12 channels, 12-250 VAC, channel-to-channel isolation, on/off onlyQuick Specs:AC digital output 12 channels 12-250 VAC channel-to-channel isolation on/off...
Add to Cart
The item has been added
OPTO 22
OPTO 22 - GRV-IACI-12 _ AC digital input, 12 channels, 85-140 VAC, channel-to-channel isolation
MSRP:
Now:
$380.00
Was:
OPTO 22 - GRV-IACI-12 _ AC digital input, 12 channels, 85-140 VAC, channel-to-channel isolationQuick Specs:AC digital input 12 channels 85-140 VAC channel-to-channel isolation ...
Add to Cart
The item has been added
OPTO 22
OPTO 22 - GRV-OACI-12 _ AC digital output, 12 channels, 12-250 VAC, channel-to-channel isolation
MSRP:
Now:
$495.00
Was:
OPTO 22 - GRV-OACI-12 _ AC digital output, 12 channels, 12-250 VAC, channel-to-channel isolationQuick Specs:AC digital output 12 channels 12-250 VAC channel-to-channel isolation ...
Add to Cart
The item has been added
OPTO 22
OPTO 22 - GRV-IACHV-24 _ AC input, 24 channels, 180-280 VAC
MSRP:
Now:
$380.00
Was:
OPTO 22 - GRV-IACHV-24 _ AC input, 24 channels, 180-280 VACQuick Specs:AC input 24 channels 180-280 VAC Part of the groov EPIC® system, the GRV-IACHV-24 AC digital input module...
Add to Cart
The item has been added
OPTO 22
OPTO 22 - GRV-IDCIS-12 _ DC digital input, 12 channels, 10-30 V, channel-to-channel isolation, on/off status only
MSRP:
Now:
$300.00
Was:
OPTO 22 - GRV-IDCIS-12 _ DC digital input, 12 channels, 10-30 V, channel-to-channel isolation, on/off status onlyQuick Specs:DC digital input 12 channels 10-30 V channel-to-channel isolation on/off...
Add to Cart
The item has been added
OPTO 22
OPTO 22 - GRV-IDCI-12 _ DC digital input, 12 channels, 10-30 V, channel-to-channel isolation
MSRP:
Now:
$380.00
Was:
OPTO 22 - GRV-IDCI-12 _ DC digital input, 12 channels, 10-30 V, channel-to-channel isolationQuick Specs:DC digital input 12 channels 10-30 V channel-to-channel isolation The...
Add to Cart
The item has been added