OPTO 22 - GRV-IACIHV-12 _ AC input, 12 channels, 180-280 VAC, channel-to-channel isolation
Write a Review
Write a Review
OPTO 22
OPTO 22 - GRV-IACIHV-12 _ AC input, 12 channels, 180-280 VAC, channel-to-channel isolation
MSRP:
Now:
$320.00
Was:
(You save
)
- Brand
- OPTO 22
- SKU:
- GRV-IACIHV-12
- UPC:
OPTO 22 - GRV-IACIHV-12 _ AC input, 12 channels, 180-280 VAC, channel-to-channel isolation
Quick Specs:
- AC input
- 12 channels
- 180-280 VAC
OPTO 22 - GRV-IACIHV-12 _ AC input, 12 channels, 180-280 VAC, channel-to-channel isolation
Quick Specs:
- AC input
- 12 channels
- 180-280 VAC
- channel-to-channel isolation
The GRV-IACIHV-12 is part of the groov EPIC® system. This AC digital input module senses status from up to 12 devices such as pumps, fans, and motors that use a 180 - 280 VAC. The GRV-IACIHV-12 provides channel-to-channel isolation and a full set of features, including:
NOTE: For projects that require only on/off status, see the GRV-IACIHVS-12, a lower-cost option.
- On/off state
- On/off latching
- On/off totalization
- Frequency measurement
- Period measurement
- Pulse measurement
NOTE: For projects that require only on/off status, see the GRV-IACIHVS-12, a lower-cost option.
Specifications:
| Feature | GRV-IACHV-24 | GRV-IACHVS-24 | GRV-IACIHV-12 | GRV-IACIHVS-12 |
| Number of channels | 24 | 24 | 12 | 12 |
| Channel-to-channel isolation | x | x | ||
| On/off state | x | x | x | x |
| On/off latching | x | x | ||
| On/off totalization | x | x | ||
| Frequency measurement | x | x | ||
| Period measurement | x | x | ||
| Pulse measurement | x | x |
| Specification | GRV-IACHV-24 | GRV-IACHVS-24 | GRV-IACIHV-12 | GRV-IACIHVS-12 |
| Nominal Input Voltage Range (RMS) | 180 - 280 VAC | 180 - 280 VAC | 180 - 280 VAC | 180 - 280 VAC |
| Turn-on Voltage | 180 VAC | 180 VAC | 180 VAC | 180 VAC |
| Turn-off Voltage | 35 VAC | 35 VAC | 35 VAC | 35 VAC |
| Input Impedance (±5%) | 532 kOhms | 532 kOhms | 271 kOhms | 271 kOhms |
| Operating Frequency | 40 Hz to 400 Hz | 40 Hz to 400 Hz | 40 Hz to 400 Hz | 40 Hz to 400 Hz |
| Turn-on Time (typical) | 30 ms at V | 30 ms at V | 30 ms at V | 30 ms at V |
| Turn-off Time (typical) | 30 ms at V | 30 ms at V | 30 ms at V | 30 ms at V |
| Isolation (field-to-logic) | 300 VAC, 1500 V Transient | 300 VAC, 1500 V Transient | 300 VAC, 1500 V Transient | 300 VAC, 1500 V Transient |
| Isolation (channel-to-channel) | N/A | N/A | 300 VAC working | 300 VAC working |
| Number of Channels | 24 | 24 | 12 | 12 |
| Chassis Power Consumption | 1.0 W | 1.0 W | 1.0 W | 1.0 W |
| Wire Size | 28 - 14 AWG | 28 - 14 AWG | 28 - 14 AWG | 28 - 14 AWG |
| Torque, connector screw | 2.5 in-lb (0.28 N-m) | 2.5 in-lb (0.28 N-m) | 2.5 in-lb (0.28 N-m) | 2.5 in-lb (0.28 N-m) |
| Torque, hold-down screw | 3.5 in-lb (0.4 N-m) | 3.5 in-lb (0.4 N-m) | 3.5 in-lb (0.4 N-m) | 3.5 in-lb (0.4 N-m) |
| Temperature (operating) | -20 °C to +70 °C | -20 °C to +70 °C | -20 °C to +70 °C | -20 °C to +70 °C |
| Temperature (storage) | -40 °C to +85 °C | -40 °C to +85 °C | -40 °C to +85 °C | -40 °C to +85 °C |
| Relative Humidity (non-condensing) | 5 - 95% | 5 - 95% | 5 - 95% | 5 - 95% |
| Agency Approvals | UL/cUL (Class 1 Div. 2)a; CE, ATEX (Category 3, Zone 2), RoHS; DFARS; CB Scheme; UKCA | |||
| Warranty | Lifetime | Lifetime | Lifetime | Lifetime |
| a For use in hazardous locations, equipment must be mounted in an enclosure that meets the requirements of the National Electrical Code, ANSI/NFPA 70, and ANSI/ISA-61010-1 (82.02.01). | ||||
0 Reviews Hide Reviews Show Reviews
OPTO 22
OPTO 22 - GRV-IACIHVS-12 _ AC input, 12 channels, 180-280 VAC, channel-to-channel isolation, on/off state only
MSRP:
Now:
$240.00
Was:
OPTO 22 - GRV-IACIHVS-12 _ AC input, 12 channels, 180-280 VAC, channel-to-channel isolation, on/off state onlyQuick Specs:AC input 12 channels 180-280 VAC channel-to-channel isolation on/off state...
Add to Cart
The item has been added
OPTO 22
OPTO 22 - GRV-IACI-12 _ AC digital input, 12 channels, 85-140 VAC, channel-to-channel isolation
MSRP:
Now:
$320.00
Was:
OPTO 22 - GRV-IACI-12 _ AC digital input, 12 channels, 85-140 VAC, channel-to-channel isolationQuick Specs:AC digital input 12 channels 85-140 VAC channel-to-channel isolation ...
Add to Cart
The item has been added
OPTO 22
OPTO 22 - GRV-OACI-12 _ AC digital output, 12 channels, 12-250 VAC, channel-to-channel isolation
MSRP:
Now:
$405.00
Was:
OPTO 22 - GRV-OACI-12 _ AC digital output, 12 channels, 12-250 VAC, channel-to-channel isolationQuick Specs:AC digital output 12 channels 12-250 VAC channel-to-channel isolation ...
Add to Cart
The item has been added
OPTO 22
OPTO 22 - GRV-IACIS-12 _ AC digital input, 12 channels, 85-140 VAC, channel-to-channel isolation, on/off state only
MSRP:
Now:
$240.00
Was:
OPTO 22 - GRV-IACIS-12 _ AC digital input, 12 channels, 85-140 VAC, channel-to-channel isolation, on/off state onlyQuick Specs:AC digital input 12 channels 85-140 VAC channel-to-channel isolation...
Add to Cart
The item has been added
OPTO 22
OPTO 22 - GRV-IACHV-24 _ AC input, 24 channels, 180-280 VAC
MSRP:
Now:
$320.00
Was:
OPTO 22 - GRV-IACHV-24 _ AC input, 24 channels, 180-280 VACQuick Specs:AC input 24 channels 180-280 VAC Part of the groov EPIC® system, the GRV-IACHV-24 AC digital input module...
Add to Cart
The item has been added