Absolute Process Instruments CS-AC-1 _ transmitter. Fully isolated.
Write a Review
Absolute Process Instruments
Absolute Process Instruments CS-AC-1 _ transmitter. Fully isolated.
- Brand
- Absolute Process Instruments
- SKU:
- CS-AC-1
- UPC:
Absolute Process Instruments CS-AC-1 _ transmitter. Fully isolated.
Features:
- Self-Powered
- NO or
Absolute Process Instruments CS-AC-1 _ transmitter. Fully isolated.
Features:
- Self-Powered
- NO or NC Solid State Switch
- Potentiometer Adjustable Setpoint
- LED Status Indicator
Applications:
- Detect Lighting Status
- Detect Motor, Pump, Conveyor Jams and Overloads
- Heater Break Detection
The CS-AC series current switches consist of a current transformer, signal conditioner, and limit alarm in one compact package. The CS-AC series products are self-powered, operate over a wide frequency range, and contain a universal solid-state output that will trip when a field adjustable setpoint is exceeded.
The CS-AC series are designed to withstand harsh industrial environments. They can be mounted in virtually any position and either panel mounted using the built-in mounting bracket or hung directly on the wires and secured with a wire tie. The split core case design makes installation in new or existing applications very quick and easy since the product can be snapped shut around the wire to be measured.
The built-in current transformer physically isolates the high current from the limit alarm circuitry making this product much safer to use than other products or methods.
Configuration and installation are simple. The switch is powered by the induction from the line being monitored. The AC current is measured by the built-in current transformer, eliminating the need for both power and input wiring. Once installed around the wire to be measured, only two wire connections are necessary for the solid state output.
The CS-AC-1 includes a"normally closed" solid state output. Both models include a status LED that flashes slowly if the setpoint has not been exceeded (nonalarm condition) and flashes rapidly if the setpoint has been exceeded (alarm condition).
Specifications Table:
Switch Type and Rating |
|
Setpoint Adjustment | 4 turn potentiometer |
Hysteresis | Approximately 5% of setpoint |
LED Indication |
|
Response Time | 120 milliseconds |
Frequency Range | 6 to 100 Hz |
Overload |
|
Isolation Voltage | UL listed to 1270 VAC, tested to 5000 VAC |
Power Supply | None, self-powered |
Sensing Aperture | 0.85" x 0.85" square (21.5 mm x 21.5 mm) |
Case | UL 94V-0 flammability rated |
Environmental |
|
Listings | UL & CUL 508 industrial control equipment, CE certified |
Setpoint | 1,75 A min., 150 A max. |
Solid State Switch Rating | 0.20 A at 135 VAC/VDC |
0 Reviews Hide Reviews Show Reviews
Absolute Process Instruments
Absolute Process Instruments CTX-AC-1 _ transmitter. Fully isolated.
Absolute Process Instruments
Absolute Process Instruments CTX-AC-3S _ transmitter. Fully isolated.
Absolute Process Instruments
Absolute Process Instruments CTX-AC-4S _ transmitter. Fully isolated.
Absolute Process Instruments
Absolute Process Instruments CTX-AC-2 _ transmitter. Fully isolated.
Absolute Process Instruments