APPLICATION:
Relaying and Metering
FREQUENCY:
50-400 Hz.
Crompton 780-751 _ Current Transformer , Current Ratio - 750:5, Relay - C100
APPLICATION:
Relaying and Metering
FREQUENCY:
50-400 Hz.
INSULATION LEVEL:
600 Volts. 10 kV BIL. full wave
CONTINUOUS THERMAL RATING FACTOR:
50:5 thru 1200:5 2.0 at 30°C amb, 1.5 at 55°C amb, 1500:5 thru 4000:5 1.5 at 30ºC amb., 1.33 at 55ºC amb.
WINDOW DIAMETER:
6.50
APPROXIMATE WEIGHT:
30 lbs.
CONNECTIONS:
-Secondary terminals are No. 10-32 brass screws with one flat washer, lockwasher and regular nut.
Specifications:
- Catalog Number: 780-751
- Current Ratio: 750:5
- Relay: C100
- Weight in lbs: 30
- Model: 780
- Window Size: 6.5
- Width: 9.88
- Height: 9.88
- Depth: 3.38
Specifications Sheet:
0 Reviews Hide Reviews Show Reviews
Crompton
Crompton 780-801 _ Current Transformer , Current Ratio - 800:5, Relay - C100
MSRP:
Now:
$279.55
Was:
Crompton 780-801 _ Current Transformer , Current Ratio - 800:5, Relay - C100APPLICATION: Relaying and Metering FREQUENCY: 50-400 Hz. INSULATION LEVEL: 600 Volts. 10 kV BIL. full wave CONTINUOUS...
Add to Cart
The item has been added
Crompton
Crompton 780-102 _ Current Transformer , Current Ratio - 1000:5, Relay - C100
MSRP:
Now:
$297.73
Was:
Crompton 780-102 _ Current Transformer , Current Ratio - 1000:5, Relay - C100APPLICATION: Relaying and Metering FREQUENCY: 50-400 Hz. INSULATION LEVEL: 600 Volts. 10 kV BIL. full wave CONTINUOUS...
Add to Cart
The item has been added
Crompton
Crompton 780-601 _ Current Transformer , Current Ratio - 600:5, Relay - C100
MSRP:
Now:
$277.07
Was:
Crompton 780-601 _ Current Transformer , Current Ratio - 600:5, Relay - C100APPLICATION: Relaying and Metering FREQUENCY: 50-400 Hz. INSULATION LEVEL: 600 Volts. 10 kV BIL. full wave CONTINUOUS...
Add to Cart
The item has been added
Crompton
Crompton 780-322 _ Current Transformer , Current Ratio - 3200:5, Relay - C100
MSRP:
Now:
$348.38
Was:
Crompton 780-322 _ Current Transformer , Current Ratio - 3200:5, Relay - C100APPLICATION: Relaying and Metering FREQUENCY: 50-400 Hz. INSULATION LEVEL: 600 Volts. 10 kV BIL. full wave CONTINUOUS...
Add to Cart
The item has been added
Crompton
Crompton 780-352 _ Current Transformer , Current Ratio - 3500:5, Relay - C100
MSRP:
Now:
$348.38
Was:
Crompton 780-352 _ Current Transformer , Current Ratio - 3500:5, Relay - C100APPLICATION: Relaying and Metering FREQUENCY: 50-400 Hz. INSULATION LEVEL: 600 Volts. 10 kV BIL. full wave CONTINUOUS...
Add to Cart
The item has been added
Crompton
Crompton 780-750 _ Current Transformer , Current Ratio - 75:5, Relay - C10
MSRP:
Now:
$277.07
Was:
Crompton 780-750 _ Current Transformer , Current Ratio - 75:5, Relay - C10APPLICATION: Relaying and Metering FREQUENCY: 50-400 Hz. INSULATION LEVEL: 600 Volts. 10 kV BIL. full wave CONTINUOUS THERMAL...
Add to Cart
The item has been added
Crompton
Crompton 112-751 Current Transformer , Current Ratio - 750:5*
MSRP:
Now:
$173.17
Was:
Crompton 112-751 Current Transformer , Current Ratio - 750:5*Application: Metering Frequency: 50 400Hz Insulation Level: 600 Volts, 10kV BIL full wave Terminals are brass studs No. 8 32 with one...
Add to Cart
The item has been added
Crompton
Crompton 299-751 Current Transformer , Current Ratio - 750:5
MSRP:
Now:
$132.97
Was:
Crompton 299-751 Current Transformer , Current Ratio - 750:5APPLICATION: Metering FREQUENCY: 50-400 Hz. INSULATION LEVEL: 600 Volts. 10 kV BIL. full wave WINDOW DIAMETER: 1.50, 2.25, 3.0, 3.38, 3...
Add to Cart
The item has been added
Crompton
Crompton 785-751 _ Current Transformer , Current Ratio - 750:5, Relay Class - C200
MSRP:
Now:
$642.61
Was:
Crompton 785-751 _ Current Transformer , Current Ratio - 750:5, Relay Class - C200APPLICATION: Relaying and Metering FREQUENCY: 50-400 Hz. INSULATION LEVEL: 600 Volts. 10 kV BIL. full wave CONTINOUS...
Add to Cart
The item has been added