Calibration data, 5 test points, test date Accuracy Accuracy includes linearity, hysteresis, repeatability Standard accuracy: ±0.25% of full scale ±1 least significant digit HA accu
Calibration data, 5 test points, test date Accuracy Accuracy includes linearity, hysteresis, repeatability Standard accuracy: ±0.25% of full scale ±1 least significant digit HA accuracy option: ±0.1% FS ±1 LSD, see ranges for availability Sensor hysteresis: ±0.015% FS, included in accuracy Sensor repeatability:±0.01% FS, included in accuracy Display 3 readings per second nominal display update rate Ranges to 2000: 3.5 digit (1999) LCD, 0.5" H digits Ranges >2000: 4 digit LCD, 0.5" H digits, 5 character 0.25" H alphanumeric lower display BL models: Red LED display backlight Batteries, Low Battery Indication, Battery Life Two AA alkaline included Low battery indication on display (battery life is approximate) B ranges to 2000: 2500 hours B ranges >2000: 2000 hours BBL ranges to 2000: 180 hours BBL ranges >2000: 150 to 1500 hours Controls B ranges to 2000: Front button turns gauge on/off, starts auto shutoff timer BL ranges to 2000: Front button turns gauge on/off, starts auto shutoff timer, backlight is on when gauge is on. B ranges >2000: Front button turns gauge on/off, starts auto shutoff timer, zeros display (gauge ref. only) BL ranges >2000: Front button turns gauge on/off, starts auto shutoff timer, activates backlighting for one minute, zeros display (gauge ref. only) Auto Shutoff Factory set to 5, 10, 30 minutes, or on/off Ranges >2000 can be factory set to custom minutes or hours Calibration Ranges to 2000: Front calibration potentiometers, non-interactive zero and span, ±10% range Ranges >2000: Internal calibration buttons, non-interactive zero, span, and linearity, ±10% of range
CECOMP F4B1BARA1.000 bar absolute to 0Ranges and Resolution See table below. Select range and default engineering units. Consult factory for special engineering units. Units may be changed to any...
Cecomp F4BBLCalibration data, 5 test points, test date Accuracy Accuracy includes linearity, hysteresis, repeatability Standard accuracy: ±0.25% of full scale ±1 least significant digit HA accuracy...
CECOMP F4BBL30INHGA30.0 inches Hg absolute to 0Ranges and Resolution See table below. Select range and default engineering units. Consult factory for special engineering units. Units may be changed...
CECOMPF4B30INHGA30.0 inches Hg absolute to 0Ranges and Resolution See table below. Select range and default engineering units. Consult factory for special engineering units. Units may be changed to...
CECOMPF4B760TORRA760 torr absolute to 0Ranges and Resolution See table below. Select range and default engineering units. Consult factory for special engineering units. Units may be changed to any...