Absolute Process Instruments APD 1600 _ API DIN TRANSMITTERS, ISOLATORS & ALARMS
Write a Review
Absolute Process Instruments
Absolute Process Instruments APD 1600 _ API DIN TRANSMITTERS, ISOLATORS & ALARMS
- Brand
- Absolute Process Instruments
- SKU:
- APD 1600
- UPC:
Absolute Process Instruments APD 1600 _ API DIN TRANSMITTERS, ISOLATORS & ALARMS
Cecomp Electronics, APD 1600, Single Alarm
Absolute Process Instruments APD 1600 _ API DIN TRANSMITTERS, ISOLATORS & ALARMS
Cecomp Electronics, APD 1600, Single Alarm Trip, 0-50 mVAC to 0-300 VAC Factory Configured Input, 85-265 VAC, 60-300 VDC Power
Features with all optional accessories:
- Measurements are true RMS
- User adjustable setpoint(s)
- User adjustable deadband(s)
- 8 Amp SPDT contacts
- Input LoopTracker LED
- Alarm status LEDs
- Alarm options: LO, HI/HI, LO/LO, band alarm
- Optional reverse acting
- Optional latching alarms
- Push to test/reset
- Remote push to test/reset
- Full I/O/power isolation
- Removable plugs
- DIN rail mount without tools
- Factory Set AC Input Range
- Alarm Test, Optional Reset Button
Applications:
- Process Limit Backup Alarm
- Over or Under Voltage or Current Alarm
- Heater Break, Conveyor Jam Alarm
The APD 1600 accept an AC voltage or milliamp current input and provide a visual alarm indication and alarm relay contact outputs. The input type, range, and alarm types are factory configured. Front-accessible potentiometers are used to adjust alarm setpoint and deadband.
LoopTracker and Alarm Status LEDs
API exclusive features include a LoopTracker LED that varies in intensity with changes in the process input signal. A red/green bi-color alarm status LED visually indicate alarm status. These LEDs provide a quick visual picture of your process at all times.
Output Test / Unlatch
API's exclusive Output Test button can be used to verify the alarm and system operation and also provides the additional function of unlatching the alarm when the latching option has been ordered. This feature can be remotely operated.
The output test button greatly aids in saving time during initial startup and/or troubleshooting.
Specifications Table:
Input | 0-50 mVAC to 0-300 VAC, 0-1 mAAC to 0-1000 mAAC |
Output | Two 8 Amp SPDT Relays |
Power to input isolation | 1200 V |
Common mode protection | 750 VACp or 750 VDC |
AC Input Range | Factory configured, please specify input type and range. Consult factory for special ranges.
|
Input Impedance | 220 kΩ minimum |
Input Voltage Burden (Current Input) | 1.0 VRMS maximum |
Input Frequency | 40 Hz to 1000 Hz sinusoidal |
Excitation Voltage | Factory configured, please specify excitation voltage, Refer to the sensor manufacturer's recommendations.
|
Standard Alarm Configuration | Single setpoint dual SPDT relays. HI alarm, non-latching, normal acting |
Setpoint | 12 turn potentiometer adjustable from 0 to 100% of span |
Deadband | 12 turn potentiometer adjustable from 1 to 100% of span |
Response Time | 70 milliseconds typical |
Ambient Temperature Range and Stability | 10°C to +60°C operating ambient |
Connectors | Four 4-terminal removable connectors, 14 AWG max wire size |
Power | 85-265 VAC, 50/60 Hz or 60-300 VDC, 2 W maximum |
0 Reviews Hide Reviews Show Reviews
Absolute Process Instruments
Absolute Process Instruments APD 1400 _ API DIN TRANSMITTERS, ISOLATORS & ALARMS
Absolute Process Instruments
Absolute Process Instruments APD 1020 _ API DIN TRANSMITTERS, ISOLATORS & ALARMS
Absolute Process Instruments
Absolute Process Instruments APD 1080 _ API DIN TRANSMITTERS, ISOLATORS & ALARMS
Absolute Process Instruments
Absolute Process Instruments APD 1600 D _ AC Input Alarm Trips, Isolated
Absolute Process Instruments
Absolute Process Instruments APD 7010 _ transmitter. Fully isolated.
Absolute Process Instruments
Absolute Process Instruments APD 7500 _ transmitter. Fully isolated.
Absolute Process Instruments
Absolute Process Instruments APD 8000 _ transmitter Fully isolated.
Absolute Process Instruments
Absolute Process Instruments APD 8000 D _ transmitter Fully isolated.
Absolute Process Instruments