AEMC PowerPad? III Model 8436 w/4 196A-24-BK (AmpFlex?- Waterproof IP67 )
$6,795.00
- Brand
- Aemc
- SKU:
- 2136.44
- UPC:
- 6.85E+11
- Availability:
- Discontinued
AEMC PowerPad? III Model 8436 w/4 196A-24-BK (AmpFlex?- Waterproof IP67 ) The PowerPad??III Model 8436 is a three-phase power quality analyzer that is easy-to-use, compact and shock resistant. It enables technicians and engineers to measure and carry out diagnostics and power quality work on one-, two- or three- phase networks. Five voltage and four current inputs are provided. It is IEC 61000-4-30 Class B and safety rated to 600V CAT IV. It is rated IP67 when used with the flexible sensor Ampflex??196A. The Model 8436 can record 2GB of trend data on a memory card. Additional internal memory is used to let you store alarms, transients, and snapshot data. The user can store up to 50 screen snapshots, up to 210 captured transients that contain four cycles for each active input, and >16,000 alarm events from up to 40 different parameters. Trend data can also be recorded for days, weeks, or even months. Inrush current can also be captured and stored. IMPORTANT WARRANTY NOTE:?By registering online within 30 days from the date of purchase, your warranty will be extended to 3 years. Inputs? 4 Voltage / 4 Current Sample Rate 256 per Cycle 12.8kHz at 50Hz 15.36kHz at 60Hz Specification Range Measurement Range Resolution Accuracy (Typical) Volt Vrms (AC + DC) 1000V P to N2000V P to P 2 to 1000V 0.1V ?0.5% Rdg + 200mV Vpk 1414V 2 to 1000V 0.1V ?3% Rdg + 2V Vrms Half Cycle 1000V P to N2000V P to P 2 to 1000V 0.1V ?0.8% Rdg + 1V Amps (accuracy excluding clamp accuracy) Amps (AC + DC) SR193 & MR193MN193 5AMN193 100A 1 to 1000A5mA to 5A100mA to 100A 0.1A1mA10mA ?0.5% Rdg + 200mA?0.5% Rdg + 2mA?0.5% Rdg + 20mA AmpFlex& MiniFlex? Range 100ARange 6500ARange 10kA 100mA to 100A10 to 6500A10A to 10kA 10mA0.1A & 1A1A ?0.5%? Rdg + 30mA?0.5%? Rdg + 3A?0.5%? Rdg + 3A Apk SR193 & MR193MN193 5AMN193 100A 1 to 1414A5mA to 7.017A100mA to 141.4A 0.1A1mA10mA ?1% Rdg + 2A?1% Rdg + 20mA?1% Rdg + 200mA ApkAmpFlex & MiniFlex? Range 100ARange 6500ARange 10kA 100mA to 100A10 to 6500A10A to 10kA 1A0.1A & 1A1A ?3% Rdg + 600mA?3%? Rdg + 5A?3%? Rdg + 5A A Half Cycle SR193 &MR193MN193 5AMN193 100A 1 to 1200A5mA to 6A100mA to 120A 0.1A1mA10mA ?1% Rdg + 1A?1% Rdg + 10mA?1% Rdg + 100mA Frequency 40 to 70Hz ? 0.01 ?0.01Hz Power Watts (VA, var) P-Q-S Probes: AmpFlex, MiniFlex 10mW to 10MW10mW to 10MW 4 digits min4 digits min ?1% Rdg?1.5% Rdg Power Factor (Cos ????/DPF) ? -1.000? to 1.000 0.001 ?1? for ????,+5 cts for cos ???? Energy kWh (kVAh, kvarh) P-Q-S 1mWh to 9,999,999MWh (MVAh, Mvarh) ?1% Rdg Harmonics DC, 1 to 50 Volts & Amp % frAbsolute VAbsolute ATHD 0.0 to 1500%0.0 to 100%0.0 to 1000V0.0 to 1000A0.0 to 999.9% 0.1%0.1%0.1V0.1A0.1% ?2.5% Rdg + 5cts?2.5% Rdg + 5cts?2.5% Rdg + 1V?2% Rdg + 1A?2.5% Rdg + 5cts Phase Angle ? -179? to +180? 1? ?1.5? +1?x(n/12.5) Also display Energy loss, Flicker, Plt (2H), Pst (10min), Unbalance V% & A% General Features Programmable Alarm Up to 40 types: up to 16,362 recorded max Transient Capture Up to 210 Snapshot Up to 50 (screen BMP + all channels data) Interface Isolated USB, SD card, and Dataview software for real time data, configuration, and reporting included Memory SD card (SDHC compliant, not formatted) standard, for trend Data, Internal memory for In-Rush, transients and alarms Display Color TFT 320 x 240 (1/4 OFT) with graphic representation of system parameters and measurements Real-Time Clock Time and date stamp for Trend mode, Transient display, System Monitor and event capture Power Supply External from 110V to 1000V DC to 440Hz Charging Time 6 hours approx. Battery Backup Rechargeable 9.6V NiMH 4000mA battery pack Battery Life ??10hrs when display ON Dimensions (L x W x H) 10.6 x 9.85 x 7.09?? (270 x 250 x 180mm) Weight 8.16 lbs (3.7kg) Altitude Operating 2000m (6560ft) Operating Temperature 32? to 122?F (0? to 50?C) Storage Temperature -4? to 122?F (-20? to 50?C) IP Rating IP67 per IEC 60529 when housing close and A196 sensor used Safety IEC/EN 61010-1 (1000V CAT III-600V CAT IV), IEC 1326-1