Accuenergy Acuvim IIBN-M-333-P2 B ACnet Power/Energy Meter, DIN rail, 333 mV input, 60 Vdc
$345.00
- Brand
- Accuenergy
- SKU:
- Acuvim IIBN-M-333-P2
Accuenergy Acuvim IIBN-M-333-P2 B ACnet Power/Energy Meter, DIN rail, 333 mV input, 60 Vdc
Description:
DIN Rail Transducer; AcuCT-Flex RCT Input; 20-60Vdc Control Power
Track Specifications via Part Number:
Additional Informations:
Accuenergy Acuvim IIBN-M-333-P2 Offers
The Accuenergy Acuvim IIBN has a built-in BACnet communication module specifically designed to monitor and collect real-time revenue-grade electrical data for building control and automation applications. This model includes the Acuvim IIBN basic unit with 333mV current transformer input, a 20 to 60V DC power supply, and DIN-rail mount transducer without display.
Features
- ANSI C12.20 Class 0.2 and IEC 62053-22 0.2s class revenue grade accuracy
- Built-in BACnet-IP protocol for integration with BAS and other monitoring and control systems
- Measures essential electrical system parameters in single element, two element and three element systems
- Directly measures up to 400Vl-n 690Vl-l without potential transformers
- Monitors all essential electrical system parameters in real-time
- Supports all types of CT from solid, split core and flexible Rogowski Coil, ideal for new and retrofit metering projects
- Secure access to meter via HTTPs encrypted webpage
Applications
The Acuvim IIBN is specially designed for these applications.
- Tenant Sub Metering
- Data Center Monitoring
- Building Automation
- Industrial Facility Metering
- Commercial Building Facility
Acuenergy Acuvim IIBN series Specifications
Current Inputs | Nominal Current | Channel 1 (5A), Channel 2 (1A), Channel 3 1A(333mV), Channel 4 1A(100mV Rope-CT), Channel 5 1A(80mA/100mA/200mA) |
Metering Range | Channel 1 (0~10A), Channel 2 (0~2A), Channel 3 (0~1.2A), Channel 4 (0~1.2A), Channel 5 (0~1.2A) |
Pickup Current | Channel 1 (5mA), Channel 2 (1mA), Channel 3 (5mA), Channel 4 (5mA), Channel 5 (5mA) |
Withstand | 20Arms Continuous, 0.1% of Nominal, 100Arms for 1 second, Non-Recurring |
Burden | 0.05VA (Typical) @ 5Arms |
Accuracy | 0.2% Full Scale |
Voltage Inputs | Nominal Full Scale | 400Vac L-N, 690Vac L-L (+20%) |
Withstand | 1500Vac Continuous, 2500Vac, 50/60Hz for 1 Minute |
Input Impedance | 2Mohm per Phase |
Metering Frequency | 45Hz~65Hz, 300Hz ~ 500Hz |
Pickup Voltage | 10Vac |
Accuracy | 0.2% Full Scale |
AC/DC Control Power | Operating Range | 100~415Vac, 50/60Hz; 100~300Vdc |
Burden | 5W |
Frequency | 50/60Hz |
Withstand | 3250Vac, 50/60Hz for 1 minute |
AC/DC Control Power | Operating Range | 100~415Vac, 50/60Hz; 100~300Vdc |
Burden | 5W |
Frequency | 50/60Hz |
Withstand | 3250Vac, 50/60Hz for 1 minute |
Operating Environment | Operation Temperature | - 40 to 85°C |
Relative Humidity | 5% to 95% Non-Condensing |